EKS – rectangular duct heaters
Used in ventilation systems as heaters or preheaters, protecting the ventilation unit from freezing.
Frame is made using Aluzinc coated steel, which is highly resistant to corrosion.
Heating elements are made from stainless steel AISI304.
All heaters are manufactured with thermal protection – automatic (50°C) and manual (100°C).
Standard sizes: 400×200 | 500×200 | 500×250 | 500×300 | 600×350 | 700×400 | 800×500 | 1000×500
Other sizes available upon request.
Possible power output- 0.3kW – 200kW, depending on chosen control type.
Various control methods and accessories listed below.
Non-standard solutions possible.
Accessories
Controller for three-phase electric heaters with power up to 240kW. Controls by supply or extract air temperature sensors* or an external 0..10VDC control signal.
Extra steps activated by sequential or binary mode, depending on heater power.
Models and maximum outputs:
| Model | Triac step | Extra steps | Voltage | Max. output |
|---|---|---|---|---|
| EKR 15.1 | 15kW | 1x5A/230V | 3x400V | 30kW |
| EKR 15.1P | 15kW | 4x5A/230V | 3x400V | 240kW |
Controller for three-phase electric heaters with power up to 480kW. Controls by supply or extract air temperature sensors* or an external 0..10VDC control signal.
Extra steps activated by sequential or binary mode, depending on heater power.
Models and maximum outputs:
| Model | Triac step | Extra steps | Voltage | Max. output |
|---|---|---|---|---|
| EKR 30 | 30kW | 1x5A/230V | 3x400V | 60kW |
| EKR 30P | 30kW | 4x5A/230V | 3x400V | 480kW |
PS – mechanical protection against loss or insufficient airflow with differential pressure switch. The heater if not allowed to heat unless a minimum airflow of 1,5m/s is reached.
By ordering the PS, an internal contactor for power supply is added to the heater as well.
Contact our sales department for more information
Stand-alone heater with internal controls and temperature setpoint on casing. Measures the temperature and works autonomously when heating is needed.
Į komplektą įeina šildytuvas ir kanalinis tiekiamo oro temperatūros jutiklis TJ-K10K.
Accessories
PS – mechanical protection against loss or insufficient airflow with differential pressure switch. The heater if not allowed to heat unless a minimum airflow of 1,5m/s is reached.
By ordering the PS, an internal contactor for power supply is added to the heater as well.
Contact our sales department for more information
Stand-alone heater with internal controls. Setpoint controlled via external TR5K or TR5KNTC10 controller. Measures the temperature and works autonomously when heating is needed.
Supply air temperature sensor TJ-K10K is included in the box.
TR5K or TR5KNTC10 should be ordered separately.
Accessories
PS – mechanical protection against loss or insufficient airflow with differential pressure switch. The heater if not allowed to heat unless a minimum airflow of 1,5m/s is reached.
By ordering the PS, an internal contactor for power supply is added to the heater as well.
Contact our sales department for more information
Accessories
PS – mechanical protection against loss or insufficient airflow with differential pressure switch. The heater if not allowed to heat unless a minimum airflow of 1,5m/s is reached.
By ordering the PS, an internal contactor for power supply is added to the heater as well.
Contact our sales department for more information
Stand-alone heater controlling air temperature from -10°C to +50°C. Protection from loss of airflow by airflow sensor PTC and diffeal pressure switch PS.
With extra protections and a broad choice of setpoint temperature, the heater is a great choice for preheating the air before a heat exchanger to prevent frost.
Supply air temperature sensor TJ-K10K is included in the box.
Accessories
Heater can have different setpoint values. Maximum temperature – +50°C.
For different setpoint values contact our sales department.
Heater controlled via external 6..24V PWM signal.
Equipped with an extra safety thermostat set at 70°C to protect internal components.
Accessories
PS – mechanical protection against loss or insufficient airflow with differential pressure switch. The heater if not allowed to heat unless a minimum airflow of 1,5m/s is reached.
By ordering the PS, an internal contactor for power supply is added to the heater as well.
Contact our sales department for more information